Vue de la page 0
1USSC 851846 rev 0
Model: 1600EF
Wood or Coal External Furnace
C
S
S
U
C
O
M
P
A
N
Y
U
N
I
T
E
D
S
T
A
T
E
S
S
T
O
V
E
United States Stove Company • 227 Industrial Park Road, P.O. Box 151 • South Pittsburg, TN 37380 • www.usstove.com
SAFETY NOTICE:
If this furnace is not properly installed, a house re may result! For your safety, follow these installation
instructions. Contact local building or re ofcials about restrictions and installation requirements in your
area. This furnace must be installed by a qualied technician. Keep these instructions for future reference.
Installation/Operator’s Manual
Safety Tested to UL 391
Vue de la page 0
1 2 3 4 5 6 ... 23 24

Résumé du contenu

Page 1 - Wood or Coal External Furnace

1USSC 851846 rev 0Model: 1600EFWood or Coal External FurnaceCSSUCOMPANYUNITED STATES STOVEUnited States Stove Company • 227 Industrial Park Road, P.O.

Page 2 - UNIT DIMENSIONS

10 USSCAll electrical connections should be done by a qualied electrician.1. To replace the Honeywell Limit Control (A): Unplug from power s

Page 3 - Print Name Signature Date

11USSCThis furnace comes from the factory with the rebrick in-stalled. However, if brick replacement is necessary, follow these instructions. Before

Page 4 - Fold Here

12 USSCAfter installation of the furnace is complete, it is ready for operation. The Honeywell Limit Control, in conjunction with a wall thermo

Page 5 - DISCLAIMER NOTICE

13USSC DANGER: Risk of Fire or Explosion - Do not burn garbage, plastics, gasoline, drain oil or other ammable liquids. Plastics, when burned, for

Page 6 - CHIMNEY REQUIREMENTS

14 USSC1. Problem: Smoke puffs from furnace Solution:A. Check chimney draft. Check for blocked chimney or ue pipe. Use mirror to check chimney cl

Page 9 - Ash Door

17USSCPARTS DIAGRAM AND LISTKey Description Part # Qty1 Grate Retainer 40312 22 Shaker Bar 891341 13 Shaker Grate Section 40314 54 Front Liner 40344 1

Page 10

18 USSCKey Description Part # Qty1 Weldment, Draft Tube 68872 12 Spin Draft 40379 13 3/8-16 x 2-1/2 Carriage Bolt 83503 14 Lock Nut, 3/8-16 83274 15 A

Page 11

19USSCPARTS DIAGRAMS AND LISTS - FAN CENTER CONTROLKey Description Part # Qty1 Electrical Box Cover 25742 12 Electrical Box Body 25743 13 Switch, 3-Po

Page 12 - STARTING A WOOD FIRE

2 USSCUNIT DIMENSIONSBlower SpeedSelector Switch10” HOT AIR OUTLETLimit SwitchAccess55-5/8”5-3/16”17-5/16”43-7/16”29-3/16”14-1/4”6”31-5/8”29-1/2”2-9/1

Page 13

20 USSCNOTES

Page 14

21USSCDOMESTIC HOT WATER COIL KIT - OPTIONALDOMESTIC HOT WATER COILREAR WALL OF FIREBOXTURN INSIDE NUTS UP TO END OF THREADS1. NUT2. WASHER3. GASKET23

Page 15 - WIRING DIAGRAM

22 USSCFurnaces that are capable of burning coal usually will burn both Bituminous and Anthracite coal. An-thracite is perhaps the best coal fuel beca

Page 16 - PARTS DIAGRAM

23USSCWhen the re is well established and the room is be-coming warm, partially close the dampers. Some experimenting will have to take pl

Page 17 - N/S = Not Shown

24 USSCHOW TO ORDER REPAIR PARTSThis manual will help you obtain efcient, dependable service from the fur-nace, and enable you to order repair parts

Page 18

" CUT HERE " CUT HEREWARRANTY INFORMATION CARDName__________________________________________ Telephone #: (_____)_____________City__________

Page 19

" CUT HERE " CUT HEREÊ ÉFold Here Fold HereUnited States Stove CompanyP.O. Box 151South Pittsburg, TN 37380Fold HerePLACESTAMPHERE

Page 20

5USSCINTRODUCTIONThank You for your purchase of a U.S. Stove Wood/Coal Burning External Furnace. Your decision to buy our Clay-ton Furnace was undoubt

Page 21

6 USSCClearances to combustible materials will vary with the type of ue connection used. Be sure to maintain the specied clearances for your type of

Page 22 - BULLETIN RC454

7USSCCONNECTING HOT AIR DUCTTO FURNACEWe strongly recommend that the hot air duct work be installed by a home heating specialist. If doing th

Page 23 - BANKING THE FIRE:

8 USSCINSTALLATION #1With this installation, a back draft damper (optional) is in-serted into the heat run before the plenum of the existing furnace t

Page 24 - HOW TO ORDER REPAIR PARTS

9USSCRead and follow these instructions in the event you have to replace or re-assemble components of your furnace.Insert door handle into door. From